Vehicle VOC Testing Chamber
Technical Parameters
|
Model |
CZ2-VA-120m³A-W (Customizable) |
|
Test Chamber Size |
W5000xH8000xD3000mm = 120m³ (Customizable according to customer's site conditions) |
|
Hatch Size |
W3000xH3000mm |
|
Temperature Range |
+20℃~+70℃ |
|
Temperature Uniformity/Fluctuation/Deviation |
≤2.0℃ / ≤±0.5℃ / ≤±1.0℃ |
|
Humidity Range |
40%~70%RH (Temperature range: +20℃~+40℃) |
|
Humidity Uniformity/Fluctuation/Deviation |
≤5.0%RH/≤±3.0%RH/≤±2.5%RH; |
|
Cabin Air Pressure |
5-20pa |
|
Wind Speed |
During the test, the ambient airflow velocity was ≤0.3 m/s, and the test point was located 0.5m around the vehicle inside the cabin. |
|
Fresh Air Exchange Rate |
2~10 times/hour |
|
Top Sunlight Irradiation System |
Infrared radiation, wavelength 280~3000nm, irradiance 350~1200W/m², |
|
Side Sunlight Heating System |
Infrared radiation, 3300W/group, irradiation area 1000x800mm/group, meeting ISO12219 standard. |
|
Background Concentration (mg/m³) |
1. Benzene content < 0.010; 2. Toluene ≤ 0.020; 3. Xylene ≤ 0.020; 4. Ethylbenzene ≤ 0.020; 5. Styrene ≤ 0.020; 6. Formaldehyde ≤ 0.020; 7. Acetaldehyde ≤ 0.010; 8. Acrolein ≤ 0.010; 9. TVOC content < 0.200; 10. Single VOC and aldehyde/ketone content ≤ 0.020 |
|
Noise |
70db(A) |
|
Exhaust Emissions |
Dual-row, negative pressure monitoring |
|
Protector |
Hazardous gas detectors, smoke detectors, video surveillance, electrical component protection, compressor protection, etc. |
|
Equipment Operating Environment |
Temperature and humidity 0~35℃ ≤95%RH, ambient air background ≤600μg/m³ |
|
Start-up/Running Power |
AC380V 50Hz |
Meets the test standards
Contact Us
description2