Composite Salt Dry and Wet Testing Machine - Salt Water Spray Type
Technical Parameters
|
Model |
CZZ-1000DF |
CZZ-1600DF |
CZZ-2000DF |
|
Inner Dimension WxHxD(mm) |
1200x800x1000 |
1600x800x1000 |
2000x800x1000 |
|
Outer Dimension WxHxD(mm) |
2250x1720x1220 |
2950x1720x1220 |
3550x1900x1220 |
|
Test chamber temperature range |
20℃~70℃ |
||
|
Saturated barrel temperature range |
RT~70℃ |
||
|
Humidity range |
20%~98%RH |
||
|
Brine spray volume |
15±5mm/h(120±40mL/h/80cm²) |
||
|
Brine temperature |
RT~35℃ |
||
|
Spray pipe swing angle |
±60° |
||
|
Sample placement angle |
20°±5° |
||
|
Dry-wet salt spray rapid alternation process |
Salt spray test: configurable from 1 minute to 99 hours; Drying test: configurable from 1 minute to 99 hours; Humidity test: configurable from 1 minute to 99 hours; |
||
|
Spray pattern |
Continuous spray, periodic spray, circulating spray can be selected |
||
|
Control accuracy |
Temperature deviation: ±2.0°C; Temperature deviation: ≤+2-3%RH when ≥75RH; Humidity deviation: ≤±5%RH when <75%RH |
||
|
Case material |
Inner titanium plate, outer stainless steel plate with paint |
||
|
Cooling method |
Water cooling |
||
|
Control system |
Siemens PLC + Siemens temperature module + human-machine interface |
||
|
Power supply conditions |
AC380V 50Hz (60Hz customized) three-phase four-wire + protective grounding |
||
Applications
Dry and Wet Salt Spray Rapid Alternation Process

Meets the Test Standards
Contact Us
description2