Technical Parameters
Zhongzhi offers six models of high and low temperature liquid-cooled testing machines (-30℃). All models have a temperature range of -30℃ to 95℃ and a temperature control accuracy of ±0.5℃. The main differences lie in the cooling capacity, heating capacity, and flow rate range.
|
Model |
Cooling Capacity (kW) |
Heating Capacity (kW) |
Temperature Range (℃) |
Temperature Control Accuracy (℃) |
Flow Rate Range (L/min) |
Flow Rate Control Accuracy (L/min) |
Pressure Range (kPa) |
Communication Interface |
|
CZ-CL1-5KC |
5 |
6 |
-30℃~95℃ |
±0.5 |
2-20 |
±0.1 |
0~300 |
RS485/CAN/Ethernet |
|
CZ-CL1-10KC |
10 |
9 |
-30℃~95℃ |
±0.5 |
2-30 |
±0.1 |
0~300 |
RS485/CAN/Ethernet |
|
CZ-CL1-15KC |
15 |
12 |
-30℃~95℃ |
±0.5 |
2-40 |
±0.1 |
0~400 |
RS485/CAN/Ethernet |
|
CZ-CL1-20KC |
20 |
18 |
-30℃~95℃ |
±0.5 |
2-40 |
±0.1 |
0~400 |
RS485/CAN/Ethernet |
|
CZ-CL1-25KC |
25 |
24 |
-30℃~95℃ |
±0.5 |
4-60 |
±0.2 |
0~400 |
RS485/CAN/Ethernet |
|
CZ-CL1-30KC |
30 |
27 |
-30℃~95℃ |
±0.5 |
4-60 |
±0.2 |
0~400 |
RS485/CAN/Ethernet |
Note:
1. Nominal Cooling Capacity: Rated cooling capacity of the equipment when the refrigerant temperature is 25℃ and the ambient temperature is 32℃ for air-cooled models or the cooling water temperature is 32℃ for water-cooled models. Refer to antifreeze parameters with a freezing point of -45℃.
2. Under stable load, ambient temperature, and power supply conditions, the temperature control accuracy can reach up to ±0.1℃.
3. Water-cooled models should have "-W" added to their model designation; water cooling is recommended for models with a cooling capacity of 15kW or higher.
4. Supports 2-channel and 3-channel output channels.
5. Please note if the temperature exceeds 95℃; the equipment requires pressurization. The recommended maximum temperature is no more than 120℃.
2. Under stable load, ambient temperature, and power supply conditions, the temperature control accuracy can reach up to ±0.1℃.
3. Water-cooled models should have "-W" added to their model designation; water cooling is recommended for models with a cooling capacity of 15kW or higher.
4. Supports 2-channel and 3-channel output channels.
5. Please note if the temperature exceeds 95℃; the equipment requires pressurization. The recommended maximum temperature is no more than 120℃.
Equipment Advantages
Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) offers multiple advantages, providing a stable and efficient testing environment for liquid cooling testing of automotive components.
1. Precise Temperature Control
Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) boasts a temperature control accuracy of ±0.5℃. Under stable load, ambient temperature, and power supply conditions, the temperature control accuracy can reach up to ±0.1℃, meeting the testing requirements of most automotive components.
2. Program Editing
Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) allows for the editing of 100 programs, each with 40 segments. Each segment can independently set the target temperature, holding time, heating/cooling rates, and flow parameters. The entire liquid cooling testing process can be pre-programmed and executed automatically without manual intervention.
3. Fast System Response
Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) features a fast system response, capable of completing temperature step changes within minutes, meeting dynamic testing requirements.
4. Multiple Safety Protections
Long-term liquid-cooled testing often requires continuous operation for days or even weeks. Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) is equipped with multiple safety safeguards, such as overload protection, reverse phase protection, high and low pressure protection, and low liquid level protection, ensuring safe and reliable testing.
5. Multi-Point System Status Monitoring
The system continuously monitors the equipment's operating status by collecting key operating parameters such as temperature, pressure, and flow rate in real time through multiple monitoring points. This helps users promptly identify anomalies and improve the reliability of equipment operation.
Intelligent Control Ensures Stable Testing Operation
Long-term unattended testing places higher demands on the temperature control stability and operational reliability of equipment. The Zhongzhi high and low temperature liquid-cooled testing machine (-30℃) provides stable and reliable operation for long-term continuous testing.
1. Adaptive PID Temperature Control for Stable Temperature
The entire machine adopts a PID intelligent control algorithm, which automatically adjusts the cooling capacity and heating power according to temperature changes, ensuring the system maintains a high-precision constant temperature. Even under rapid heating and cooling conditions, it ensures minimal temperature fluctuations and stable and reliable test data.
2. Monitoring of Key Components Reduces Downtime Risk
The system monitors the operating status of key components such as the compressor, circulating pump, and temperature sensor in real time. When equipment malfunctions, the system automatically alarms and takes corresponding protective measures to help ensure stable equipment operation.
3. Automatic Protection Functions Ensure Smooth Testing
The equipment has multiple safety protection functions, including overload protection, reverse phase loss protection, high and low pressure protection, and low liquid level protection. When an anomaly is detected, the system automatically executes corresponding protective measures to ensure the safety of the equipment and the product under test.
4. Automatic Data Recording for Easy Traceability and Analysis
4. Automatic Data Recording for Easy Traceability and Analysis
The system automatically records operational data such as temperature, pressure, and flow rate during the testing process and generates historical curves. Test data can be exported via USB for convenient subsequent data analysis.
5. Independently Developed Control System for Enhanced Testing Stability
Zhongzhi's high and low temperature liquid-cooled testing machine (-30℃) integrates an advanced control system to ensure stable and accurate operation of the equipment under preset conditions.
Coolant Selection
Coolant is a crucial factor affecting the stability of liquid cooling tests. A suitable coolant should be selected based on the testing requirements to ensure stable equipment operation and reliable test results.
1. Select the Appropriate Coolant Based on the Test Temperature
Different types of coolants have different applicable temperature ranges. When conducting low-temperature tests, a dedicated antifreeze with a freezing point lower than the minimum test temperature should be selected to prevent coolant freezing, which could lead to blockage of the circulation system or abnormal equipment operation.
2. Select the Appropriate Coolant According to Equipment Requirements
The flow properties of coolant change with temperature, affecting circulation efficiency. It is recommended to select a suitable cooling medium based on equipment requirements and keep the coolant clean to ensure stable heat transfer performance.
3. Regularly Check and Replace the Coolant
During long-term equipment operation, coolant performance may degrade. It is recommended to regularly check the coolant condition according to equipment maintenance requirements and replace it promptly to ensure the long-term stable operation of the liquid cooling system.
Quality Assurance
Guangdong Zhongzhi Testing Instrument Co., Ltd. was established in 2005 and has been focusing on the R&D and manufacturing of environmental reliability testing equipment. It has established a complete R&D, manufacturing, quality management and after-sales service system, and has the following qualifications and strengths:
● ISO 9001 quality management system certificate
● CE certification
● 60+ technology patents
● 38,000㎡ self-owned factory, 300+ employees
Get Your Custom Solution
Whether you need standard models or customized equipment, our engineering team will provide professional technical support based on your testing needs. Here is our project service process:
● Requirements Confirmation: Confirm the test object, equipment dimensions, temperature range, and other test parameters.
● Solution Design: Recommend suitable equipment models and develop a solution based on your testing requirements.
● Manufacturing: Organize production according to the confirmed technical solution and assemble the entire machine.
● Commissioning and Testing: After assembly, conduct overall machine commissioning to ensure stable and reliable operation.
● Equipment Delivery: After the equipment passes factory acceptance, ship the equipment according to the agreement between both parties, ensuring timely delivery.
● After-sales Service: Lifetime product maintenance.
Contact Our Team
Email: jane@dgzhongzhi.com
Phone: +86 18302053458(Whatsapp)
Website: www.zztestchamber.com
Address: No. 417, Shatian Section, Gangkou Road, Shatian Town, Dongguan City, Guangdong Province,China
Frequently Asked Questions
The following are some frequently asked questions about the high and low temperature liquid-cooled testing machine (-30°C). Please contact us directly if you have any further questions.
1. What Ramp Rates Can I Achieve Between -20°c and +95°c?
The heating and cooling rates depend on several factors. Generally, the system can achieve a faster heating and cooling rate under no-load conditions, but the rate decreases with increasing load in actual testing. If you have specific heating and cooling rate requirements, we can provide a suitable configuration solution based on your testing needs.
2. Does the System Support Multi-segment Program Editing?
Yes. The system can edit 100 programs, each with 40 segments, which can run synchronously with high and low temperature programs.
3. How Long Does the Coolant Last Before Needing Replacement?
The coolant's lifespan is typically 6 months to 2 years, depending on the coolant type, operating temperature range, usage frequency, and routine maintenance.
4. What if the Equipment Temperature Does Not Reach the Set Value?
First, check if the coolant level is sufficient and if there are any leaks in the system. Next, check if the compressor is operating normally and if the cooling system is functioning properly. If the problem persists, it may be due to insufficient refrigerant or a control system malfunction, requiring contact with a professional repair technician.
5. What Is the Difference Between a High and Low Temperature Liquid-Cooled Testing Machine and a Regular Temperature Test Chamber?
The main difference lies in the temperature control method and performance. A high and low temperature liquid-cooled testing machine uses liquid as the heat transfer medium, resulting in faster temperature changes and more precise temperature control, making it suitable for testing scenarios with high temperature response requirements. A regular temperature test chamber typically uses air circulation, resulting in slower temperature changes, but it is less expensive.
description2
Discover the Possibilities!
Have a specific testing need? Let’s discuss your environmental testing requirements.
Whether it’s customizing a standard chamber or developing a bespoke solution, we’re here to help.
Contact us