Vehicle Altitude Environment Test Chamber
Technical Parameters
|
Model |
CZ2-AQH-945m³E-WR (Customizable) |
|
Test Chamber Size |
W7000*D18000*H7500mm |
|
Temperature Range |
-55℃~+75℃ (static, normal pressure) / -45℃~+55℃ (low pressure) |
|
Humidity Uniformity/Fluctuation/Deviation |
≤2℃ (static test, atmospheric pressure) / ≤±1℃ (static test, atmospheric pressure) / ≤±2℃ (static test, atmospheric pressure) |
|
Heating/Cooling Time |
≥0.5℃/min (-40℃ to +60℃, no load, normal pressure, average) |
|
Humidity Range |
10%~95%RH (temperature range 20℃~60℃) |
|
Pressure Range |
Atmospheric pressure ~50kPa [-45℃~+55℃] Altitude approximately 5500 meters /*Note: Cool down to the set value and stabilize before reducing pressure. |
|
Buck Rate |
≥3kPa/min |
|
Fresh Air System |
Under normal pressure mode: minimum dew point temperature -40℃, minimum airflow not less than 2000 m³/h; in environments above 25℃, minimum airflow not less than 5000 m³/h. |
|
Fresh Air System |
When the oncoming fan inside the cabin is not running, ensure that the wind speed at the dynamometer placement position is ≤1.7m/s; |
|
Wind Ppeed |
288,000 m³/h |
|
Controller |
Industrial-grade 10-inch color resistive touchscreen programmable controller (independently developed controller, industrial host + touchscreen + PLC); equipped with industrial computer and control software. |
|
Protector |
Features include compressor overload and overheat protection, heater over-temperature protection switch, system overcurrent protection device, over-temperature protection, fan motor thermal overload protection, leakage protection, cooling water shortage and undervoltage protection, humidifier dry burn protection, harmful gas alarm function, smoke alarm function, flame detection alarm function, and exhaust gas and harmful gas protection and monitoring functions. |
|
Personal Protective Equipment |
Eyeglasses, protective clothing, gloves, face shields, etc.; portable oxygen cylinders, emergency call walkie-talkies, SOS flashlights, etc.; clearly visible warning signs and instructions for use of safety protective equipment; real-time security monitoring video. |
|
Protection Requirements |
Personnel operation is unrestricted in environments ranging from -40℃ to 60℃. |
|
Life Safety Protection System |
1. Equipped with a ventilation system (real-time monitoring of oxygen levels inside the chamber to determine the amount of fresh air intake). |