ZHONGZHI-The Professional Walk In Chamber Manufacturer
Zhongzhi Group was established in 2005, which is a leading analog environment and reliability test equipment overall solution provider.
Zhongzhi offers standardized and customizable walk in chamber. Its walk in chanmbers are available in a variety of configurations to meet your test requirements in terms of temperature, humidity and other aspects, such as computer terminals, automotive parts and more. Its types include walk-in high and low temperature test chamber, walk-in rapid temperature change test chamber, etc.
Contact us
Currently, we have 150+ home-stable customer bases, 30,000 + customer case support in more than 40 countries and regions around the world.
Want to improve testing efficiency and accuracy? Our climatic chamber uses advanced technology to ensure precise environmental control in a spacious testing space.
Temperature Range
Our chambers are designed to operate within a wide range of -70°C to 150°C.
Humidity Range
For applications requiring humidity control, we offer a humidity range from 20% to 98% RH, customizable to match the specific environmental conditions needed for your tests.
Heating/Cooling Rates
We can customize the heating/Cooling rates to achieve up to 3.0°C /1.0°C per minute, allowing you to quickly reach the desired temperature for time-sensitive tests.
Features and Benefits of Walk In Test Chambers
Vacuum High Temperature Resistant Glass Window
- Three layers of high temperature and explosion-proof glass with fog removal function
- Clear and distinct
- High temperature without water mist
- No frosting at low temperatures
Automotive Grade Sealing Strip
- Imported silica gel raw materials, open molding, temperature resistance high temperature 200°C low temperature -80°C
- Can be used for a long time aging resistance, the service life can reach more than 10 years
Ce Standard Power Distribution System
- The use of Schneider, Swiss Jiale and other imported brands of industrial control products professional wiring, wiring and multiple protection devices to ensure long-term stable operation of equipment
- Reasonable layout, line number arrangement
- The wiring is clear and easy to maintain
- Imported brand industrial control products
Independent Waterway Circulation Structure Design
- Independent waterway structure design system
-
Equipped with excellent water temperature controlThe temperature controller is connected to the water storage tank
- The temperature controller is connected to the water storage tank
- Reduce water consumption by 20%, reduce frequent water changes and save energy.
Green and Environmental Protection
All materials, parts, components, raw materials, etc., whether domestic or imported, are environmentally friendly products
Super Energy Saving
The test chamber refrigeration, electronic control, structure, system and process adopt energy-saving design, saving 40% energy
Intelligent Control
Automatic realization according to working conditions, fast convergence, small overshoot, high stability
System Compatibility
Configure LAN/RS232/RS485 connection, connect to MES system, and program the laboratory
Rich Customization Experience
30000+ customer case support, meet IECDIN, MIL-STD and other test standards
Our Factory
0102030405060708
01020304
01
/
What is a walk in chamber and what are its uses?
A walk in chamber is a large-scale environmental test facility that allows the user or product to enter the test space directly. It is widely used in aerospace, automotive, electronics, and pharmaceutical industries to test the performance and stability of products under extreme temperature and humidity conditions.
02
/
What is the difference between a walk in chamber and an ordinary environmental test chamber?
Walk in chambers have a larger interior space compared to ordinary test chambers, allowing them to accommodate large or batch sizes of products for testing. In addition, they are often designed with more advanced temperature control systems and stability to accommodate more stringent testing requirements.
03
/
How can I ensure test accuracy and repeatability in a walk in chamber?
The key to ensuring test accuracy and repeatability lies in selecting high-quality equipment, regular calibration and maintenance, and following strict testing procedures. In addition, the use of advanced control systems and sensors can improve test accuracy.
04
/
What is the energy consumption of walk in test chambers and what are the energy saving measures?
Walk in test chambers have relatively high energy consumption due to their large size. However, energy consumption can be effectively reduced by adopting energy-saving refrigeration technologies, optimized insulation materials and intelligent control systems.
05 /
What are the important technical parameters to consider when purchasing a walk in chamber?
When purchasing, technical parameters that should be considered include temperature and humidity ranges, temperature uniformity, temperature fluctuations, temperature ramp-up and ramp-down rates, chamber dimensions, load capacity, and complexity of the control system.
06 /
How do I perform effective routine maintenance and cleaning of my walk in chamber?
Routine maintenance includes regularly inspecting the refrigeration system, cleaning the condenser, replacing wear parts, checking the electrical system and performing an annual professional calibration. When cleaning, use soft fabrics and neutral cleaners and avoid caustic chemicals.
Discover the Possibilities!
Have a specific testing need? Let’s discuss your environmental testing requirements.
Whether it’s customizing a standard chamber or developing a bespoke solution, we’re here to help.
Contact us