Leave your message
Walk-In High and Low Temperature Humidity Test Chamber
walk-in environmental chamber

Walk-In High and Low Temperature Humidity Test Chamber

All materials, parts, components, raw materials, etc. of Zhongzhi Testing Instruments' walk-in high and low temperature humidity test chamber, whether domestic or imported, are environmentally friendly products. Not only does the energy consumption account for only 80% of similar products, but sound absorption and silencing methods are used in different places throughout the structure and mechanical working process to reduce the noise of the entire equipment and enhance customer use of the test.

    Product Specifications:

    Model

    CZ-A-4000

    (D~G)

    CZ-A-8000

    (D~G)

    CZ-A-10000

    (D~G)

    CZ-A-15000

    (D~G)

    CZ-A-20000

    (D~G)

    CZ-A-25000

    (D~G)

    CZ-A-30000

    (D~G)

    CZ-A-40000

    (D~G)

    Internal size (W×H×D) (mm) 

    1500x1800x1500

    2000x2000x2000

    2500x2200x2000

    3000x2000x2500

    4000x2000x2500

    4000x2500x2500

    4000x2500x3000

    5000x2500x3200

    External size (W×H×D) (mm) 

    2500x2100x1700

    3100x2300x2260

    3600x2300x2260

    4100x2300x2760

    5100x2300x2760

    5100x2800x2760

    5100x2800x3500

    6100x2800x3500

    Temperature range

    -70℃~+80℃(Above 80℃ is a special order) (D:-40℃ G:-70℃)

    Humidity range

    20%~95%R.H.(10%-98%R.H/5%~98%R.H are special selection conditions)

    Temperature and humidity analysis accuracy/uniformity

    0.01℃;0.1%R.H./±1.0℃;±3.0%R.H.

    Temperature and humidity control accuracy/fluctuation

    ±1.0℃;±2.0%R.H./±0.5℃;±2.0%R.H.

    Heating/Cooling rate

    About 3.0℃/minute; about 1.0℃/minute (a drop of 2℃ to 15℃ or more per minute is a special selection condition)

    Structural Characteristics:

    ● The exterior of this high low temperature test chamber can be designed with different colors or all stainless steel according to the interior design, and the interior space is made of SUS304# stainless steel;
    ● The rectangular double-layer glass viewing window can be used to observe the test product during the test. The window is equipped with a sweat-proof electric heater to prevent water vapor from condensing into water droplets;
    ● Explosion-proof lamps are installed indoors, and the product test status can be clearly observed during the test. The bottom of the test room is installed with non-slip aluminum plates for safe use;
    ● The double-layer insulation sealing strip of the door can effectively isolate the internal temperature leakage;
    ● It has a pure water filter unit that can directly filter tap water, without manual water addition, and is easy to use;
    ● The refrigeration and dehumidification system uses imported brand compressors, which have the advantages of energy saving, low noise, low energy consumption, stable performance, etc., and uses environmentally friendly refrigerants (R23, R404a);
    ● The controller uses an imported LCD display screen, which can simultaneously display the measured value, set value, time, etc.;
    ● The controller has multi-segment program editing and temperature and humidity can be done quickly (QUICK) or slope ( SLOPE) control;
    ●TEM2700 has a 7.5-inch true color LCD display with RS-232/RS-485 communication interface and a 2GB standard SD memory card, which can be connected to Ethernet; TEM880 has a 5.7-inch color display with RS-232/RS-485 communication interface (optional upon request); 
    ●The bottom of the machine is welded with channel steel into a mesh structure to increase the load-bearing capacity and will never deform during use. The bottom of the integral test chamber is equipped with mobile casters and positioning feet, and the bottom channel steel of the assembled test chamber is directly installed on the laboratory floor.

    Temperature Control Range:

    Temperature control range

    Lmplement and Meet Standards and Test Methods

    ●GB2423.1-2008/IEC6008-2-1-2007 Low temperature test method
    ●GB/T2423.2-2008 High temperature test method
    ●GJB150.3A-2009 High temperature test method
    ●GJB150.4A-2009 Low temperature test method
    ●GB2423.22-2008 Temperature change rate test method
    ●GBT2424.5-2006 Temperature test chamber performance confirmation
    ●GB/T10589-2008 Low temperature test chamber technical conditions
    ●GB/T2423.3-2008 (IEC68-2-3) Constant humidity test method
    ●GJB150.9A-2009 Damp heat test method
    ●G/BT24234-2008/IEC6008-2-30:2005 Alternating damp heat method
    ●GB/T5170.18-2005 Temperature/humidity combination cycle test equipment calibration method
    ●GB/T10586-2006 Damp heat test chamber technical conditions
    ●GBT2424.6-2006 Temperature/humidity test chamber performance confirmation
    ●GBT2424.7-2006 (Loaded) temperature test chamber measurement

    Contact Us

    As a professional test chamber manufacturer, Guangdong Zhongzhi Testing Instruments Co., Ltd. offers custom products to meet your specific testing needs, including our Walk-In High and Low Temperature Humidity Test Chamber. For more information, please feel free to contact us.